• Home
  • Cisco
  • 640-911 Introducing Cisco Data Center Networking (DCICN) Dumps

Pass Your Cisco 640-911 Exam Easy!

100% Real Cisco 640-911 Exam Questions & Answers, Accurate & Verified By IT Experts

Instant Download, Free Fast Updates, 99.6% Pass Rate

Archived VCE files

File Votes Size Date
File
Cisco.Braindumps.640-911.vv2014-10-15.by.LEIGHA.131q.vce
Votes
306
Size
1.59 MB
Date
Oct 15, 2014
File
Cisco.Actualtests.640-911.v2014-06-07.by.JEAN.81q.vce
Votes
12
Size
1.55 MB
Date
Jun 07, 2014
File
Cisco.Passguide.640-911.v2013-08-02.by.Reaper.82q.vce
Votes
44
Size
1.58 MB
Date
Aug 05, 2013
File
Cisco.ActualTests.640-911.v2013-02-14.by.Lagi.81q.vce
Votes
2
Size
1.51 MB
Date
Feb 14, 2013

Cisco 640-911 Practice Test Questions, Exam Dumps

Cisco 640-911 (Introducing Cisco Data Center Networking (DCICN)) exam dumps vce, practice test questions, study guide & video training course to study and pass quickly and easily. Cisco 640-911 Introducing Cisco Data Center Networking (DCICN) exam dumps & practice test questions and answers. You need avanset vce exam simulator in order to study the Cisco 640-911 certification exam dumps & Cisco 640-911 practice test questions in vce format.

A Comprehensive Guide to the 640-911 Exam and Its Core Technologies

The journey into the world of data center management and implementation often involves navigating a landscape of powerful technologies and the certifications that validate expertise in them. Among the significant milestones for many professionals was the Cisco 640-911 Exam, formally known as the Data Center Unified Computing Implementation (DCUCI) exam. While this specific exam code has been retired as part of Cisco's certification program evolution, the principles, technologies, and skills it covered remain profoundly relevant. This series will serve as an in-depth exploration of the concepts central to the 640-911 Exam, providing a foundational knowledge base that is essential for any modern data center engineer working with Cisco's Unified Computing System (UCS). Understanding the material from the 640-911 Exam is not just a historical exercise; it is about grasping the architectural philosophy that continues to influence data center design and operations today. This first part will lay the groundwork, introducing the system and its core architectural components.

The Historical Significance of the 640-911 Exam

The 640-911 Exam was a cornerstone of the Cisco Certified Network Professional (CCNP) Data Center certification track. Its primary focus was on the implementation and management of the Cisco UCS B-Series Blade Servers and C-Series Rack Servers. Passing this exam demonstrated a candidate's ability to install, configure, and maintain a Cisco UCS environment, a skill set that was and still is in high demand. The exam was designed to test practical knowledge, requiring engineers to understand not just the theory but also the hands-on processes of deploying servers, configuring fabric interconnects, and managing the system through the Cisco UCS Manager. The curriculum for the 640-911 Exam covered a wide array of topics, from the physical installation of components to the logical configuration of server identities through service profiles. It validated an engineer's proficiency in unifying network, storage, and compute resources into a single, cohesive platform. As data centers moved towards virtualization and cloud models, the unified and stateless nature of UCS, a central theme of the 640-911 Exam, became increasingly important. Thus, the knowledge base required for this exam provided the perfect launching point for professionals aiming to excel in the new era of data center administration and architecture.

An Introduction to Cisco Unified Computing System

At the heart of the 640-911 Exam curriculum is the Cisco Unified Computing System, or UCS. This is not merely a collection of servers; it is an integrated platform that combines industry-standard x86-architecture servers with networking and storage access capabilities. The fundamental goal of UCS is to simplify data center architecture and operations by reducing the number of devices that need to be purchased, cabled, configured, and managed. It achieves this by abstracting the server personality from the physical hardware and centralizing management for the entire system, which can scale from a single chassis to dozens of chassis with hundreds of servers. This unified approach presents numerous benefits. It dramatically reduces the complexity of cabling by using a unified fabric that can carry Ethernet, Fibre Channel, and Fibre Channel over Ethernet (FCoE) traffic over a single cable. This leads to lower capital expenditures on network adapters, switches, and cables, as well as reduced operational expenditures related to power, cooling, and management overhead. For anyone preparing for a role that involves the topics of the 640-911 Exam, understanding this core value proposition of simplification and integration is the critical first step. It is the 'why' behind all the specific configurations and components that follow.

Core Architectural Components of Cisco UCS

To truly understand the material covered in the 640-911 Exam, one must first become familiar with the primary hardware components that constitute a Cisco UCS domain. The system is built around several key pieces of equipment that work in concert. The central control point is the pair of UCS 6000 Series Fabric Interconnects. These devices provide the network connectivity and management plane for the entire system. They are the brain of the operation, running the Cisco UCS Manager software and connecting the system to the external LAN and SAN. Connected to the fabric interconnects are the UCS 5108 Blade Server Chassis. These chassis house the UCS B-Series Blade Servers, which are the primary compute resources. Each chassis contains power supplies, cooling fans, and I/O Modules (IOMs), also known as Fabric Extenders (FEX), which link the blade servers to the fabric interconnects. Additionally, the UCS platform includes C-Series Rack Servers, which can be managed as part of the same UCS domain, providing flexibility in form factor while maintaining a single point of management. Understanding the role of each component is essential for both design and troubleshooting.

The Central Role of UCS Fabric Interconnects

The UCS Fabric Interconnects are arguably the most critical component of the entire system, a concept heavily emphasized in the 640-911 Exam. They are not just switches; they are the nexus of data and management for every server within the UCS domain. Typically deployed in a high-availability pair, these devices consolidate three main types of traffic: LAN traffic, SAN traffic, and management traffic. They run the Cisco UCS Manager software, which provides the graphical and command-line interfaces for administering all the connected chassis, blades, and rack servers as a single logical entity. Physically, fabric interconnects are one-rack-unit (1RU) or two-rack-unit (2RU) devices equipped with a variety of ports, including Ethernet, Fibre Channel, and unified ports that can be configured for either. This port flexibility is key to the unified fabric concept. All traffic from the servers flows through the fabric interconnects, which then connect upstream to the corporate LAN and SAN. Their clustered configuration ensures that there is no single point of failure for the management or data plane, a crucial feature for enterprise data center environments. Mastery of fabric interconnect configuration, including their different operating modes, is a major objective of the 640-911 Exam study path.

Exploring the UCS B-Series Blade System

The Cisco UCS B-Series Blade Servers and the 5108 Chassis they reside in are a marvel of data center engineering, designed for density, efficiency, and simplicity. The chassis is a six-rack-unit (6RU) enclosure that can house up to eight half-width blade servers or four full-width blade servers, or a combination of both. It provides shared power and cooling for all the servers, significantly reducing the physical footprint and energy consumption compared to an equivalent number of traditional rack servers. A key design principle tested in the 640-911 Exam is understanding this shared infrastructure. Inside the chassis, the I/O Modules (IOMs) play a vital role. These are fabric extenders that connect the blades to the parent fabric interconnects. This design drastically simplifies cabling. Instead of each server needing multiple network and storage connections, each blade server connects to a midplane in the chassis. The IOMs then multiplex all the traffic from the blades onto a few high-speed links running up to the fabric interconnects. This architecture eliminates the need for top-of-rack switches and minimizes the cable count, a significant operational advantage that was a key selling point of UCS and a focus of the 640-911 Exam.

The Power of Cisco UCS Manager

The management philosophy of Cisco UCS is what truly sets it apart, and Cisco UCS Manager (UCSM) is the embodiment of that philosophy. UCSM is the software that resides on the fabric interconnects and provides a single pane of glass for managing the entire UCS domain. It is through this interface that administrators configure every aspect of the system, from network VLANs and storage VSANs to the identity of the servers themselves. The 640-911 Exam required a deep understanding of UCSM's graphical user interface (GUI) and command-line interface (CLI). UCSM's management is model-based. This means administrators create policies and templates for various aspects of the infrastructure, such as firmware levels, I/O configurations, and boot order. These policies are then assembled into a master template called a Service Profile. This model-driven approach ensures consistency, reduces the chance for human error, and dramatically speeds up the deployment of new servers. Instead of manually configuring dozens of settings on each new server, an administrator can simply associate a pre-defined service profile with a physical blade, and the server is configured automatically in minutes.

The Revolutionary Concept of Stateless Computing

Perhaps the most revolutionary concept introduced by Cisco UCS, and a core topic of the 640-911 Exam, is stateless computing. This is made possible by the use of Service Profiles within UCS Manager. A service profile is a software definition of a server. It contains all the information that makes a server unique: its identity, its firmware revisions, its network and storage configurations, and its boot policies. This includes elements like UUIDs, MAC addresses for virtual network interfaces, and World Wide Node Names (WWNNs) and World Wide Port Names (WWPNs) for virtual storage adapters. Because this identity is stored in a software template rather than being hard-coded into the physical hardware, the underlying servers become stateless. A physical blade server is essentially a pool of resources (CPU, memory) waiting for an identity to be applied to it. If a blade server fails, an administrator can simply disassociate the service profile from the failed hardware and associate it with a spare blade. The new blade instantly inherits the exact same identity and configuration, and the workload can be brought back online quickly with minimal disruption. This level of flexibility and hardware independence was a game-changer for data center operations.

Initial System Setup and Configuration

The 640-911 Exam preparation required practical knowledge of how to bring a new Cisco UCS system online from scratch. The initial setup process involves physically racking and cabling the components, including connecting the two fabric interconnects to each other for clustering and connecting the chassis IOMs to the fabric interconnects. Once the hardware is physically connected and powered on, the initial configuration is performed via a console connection to the primary fabric interconnect. This console-based setup script walks the administrator through the essential first steps. This includes configuring a password for the admin user, setting up the management IP address for the cluster, and defining the system name. It also involves confirming the fabric interconnect's role as the first in a new cluster. After this rudimentary setup is complete, all further configuration and management is performed through the graphical Cisco UCS Manager, which is accessed via a web browser pointed at the management IP address. This initial bootstrap process is the gateway to unlocking the full management capabilities of the platform.

Understanding Pools and Policies

A fundamental aspect of managing a UCS environment, and a key knowledge area for the 640-911 Exam, is the extensive use of pools and policies. These are foundational constructs within UCS Manager that enable the automation and scalability of the platform. Pools are collections of unique identifiers that can be assigned to servers as needed. For example, an administrator would create a pool of MAC addresses, a pool of UUIDs, and pools of WWNNs and WWPNs. When a service profile is created and needs a MAC address for a virtual NIC, it simply draws one from the predefined pool. Policies, on the other hand, define configuration rules and behaviors. There are policies for almost everything: boot order, BIOS settings, firmware management, power control, and network control. For instance, a Local Disk Policy might specify the RAID level for a server's internal drives. A Boot Policy would dictate whether the server boots from the local disk, a SAN LUN, or a network PXE server. By creating a library of these reusable pools and policies, administrators can enforce standards and ensure that every server is deployed in a consistent, predictable manner, which is a core tenet of efficient data center management.

Mastering the Cisco 640-911 Exam Technologies: A Deep Dive 

Building upon the foundational concepts introduced in the first part of this series, this second installment will delve deeper into the specific hardware components that form the Cisco Unified Computing System (UCS). A thorough understanding of the physical servers, both blade and rack-mount, as well as the intricate details of the chassis and its connectivity, was a mandatory prerequisite for success in the 640-911 Exam. While the models and specifications of the hardware have evolved, the architectural principles and the roles these components play remain consistent. This section will provide a detailed examination of the UCS B-Series blade servers, the 5108 chassis environment, the various adapter cards, and the integration of C-Series rack servers. Gaining expertise in the hardware is essential before one can effectively manage it through the software constructs covered later in this series, mirroring the learning path required for the 640-911 Exam.

A Closer Look at the UCS 5108 Blade Server Chassis

The UCS 5108 Blade Server Chassis is the physical housing for the B-Series compute nodes. Its design focuses on density, shared resources, and simplified connectivity. As a six-rack-unit enclosure, it efficiently uses vertical rack space. From the front, the chassis presents up to eight bays for half-width blade servers or four bays for full-width blade servers. This flexibility allows organizations to mix and match server types based on the specific CPU, memory, and I/O requirements of their workloads. The 640-911 Exam curriculum expected candidates to be familiar with these physical characteristics and their implications for data center planning. The rear of the chassis reveals its resource-sharing capabilities. It contains up to four power supply units (PSUs) operating in a grid-redundant configuration, ensuring high availability even with the loss of a power source. It also houses eight hot-swappable fans for cooling the entire enclosure. Most importantly, the rear of the chassis holds bays for two I/O Modules (IOMs). These IOMs are a critical piece of the UCS architecture, acting as fabric extenders that connect all eight server bays to the upstream Fabric Interconnects. This centralized I/O consolidation is a key differentiator for the UCS platform.

Dissecting the UCS B-Series Blade Servers

The UCS B-Series Blade Servers are the workhorses of the UCS blade ecosystem. These servers slide into the front of the 5108 chassis and connect to a midplane, which provides them with power, cooling, management, and I/O connectivity. Over the years, Cisco has released many generations of B-Series servers, each supporting the latest processor and memory technologies of its time. While specific model numbers were relevant for the 640-911 Exam, the core design philosophy has remained the same. Each blade is a self-contained server with its own CPUs, DIMM slots for memory, and internal drive bays for local storage. What makes the B-Series blades unique is their I/O subsystem. Instead of traditional network interface cards (NICs) and host bus adapters (HBAs), they use a specialized mezzanine-style adapter card, known as a Virtual Interface Card (VIC). This card is the server's gateway to the unified fabric. It presents a physical connection to the chassis midplane, which in turn connects to the IOMs. The VIC is designed to be virtualized, allowing for the creation of dozens of virtual NICs (vNICs) and virtual HBAs (vHBAs) that are presented to the server's operating system or hypervisor. This virtualization of I/O is a fundamental concept of UCS.

The Critical Role of I/O Modules (Fabric Extenders)

The I/O Module, or IOM, is a key enabler of the simplified architecture of the UCS B-Series system. Often referred to as a Fabric Extender (FEX), the IOM sits in the back of the blade chassis and serves as a line card for the parent Fabric Interconnect. Its purpose is to multiplex all network and storage traffic from the eight blade servers within the chassis and transport it over a small number of high-speed uplink ports to the Fabric Interconnects. This drastically reduces the number of physical cables required compared to a traditional rack server environment, a major topic within the 640-911 Exam syllabus. Each blade server has traces on the midplane that connect it to both IOMs, providing redundant paths for I/O. Similarly, each IOM has multiple uplinks that connect to its corresponding Fabric Interconnect. For example, in a standard redundant configuration, IOM A would connect only to Fabric Interconnect A, and IOM B would connect only to Fabric Interconnect B. This creates two distinct, physically separate fabric paths (Fabric A and Fabric B) from the server's adapter card all the way to the core network, ensuring high availability and load balancing. The IOM itself does no local switching; it simply tags and forwards traffic, with all policy enforcement and switching decisions being made at the parent Fabric Interconnect.

Understanding Cisco Virtual Interface Cards (VICs)

The Cisco Virtual Interface Card, or VIC, is a specialized adapter that resides on the B-Series blade servers and some C-Series rack servers. It is the endpoint that connects the compute node to the unified fabric. The 640-911 Exam required a deep understanding of the VIC's capabilities, as it is central to the stateless computing model. Unlike a traditional adapter, the VIC is an intelligent device that can be partitioned into many virtual adapters. Using Cisco's technology, a single VIC can present up to 256 virtual devices—a mix of vNICs and vHBAs—to the server's operating system. This virtualization is managed entirely through the Service Profile in UCS Manager. An administrator can define, on a per-server basis, exactly how many vNICs and vHBAs are needed, what their bandwidth parameters are, and to which VLANs or VSANs they should be connected. This allows for extremely granular and flexible I/O configuration that is tailored to the specific needs of an application. For instance, a database server might be provisioned with multiple vNICs for public, private, and management traffic, along with two vHBAs for redundant SAN connectivity, all from a single physical VIC adapter. This hardware-level I/O virtualization provides performance benefits and simplifies hypervisor networking.

Exploring the UCS C-Series Rack Servers

While the B-Series blade system is often the centerpiece of a UCS deployment, the platform also fully supports C-Series Rack Servers. These are standard form-factor servers (e.g., 1RU or 2RU) that can be installed in any industry-standard rack. The 640-911 Exam covered the integration of these servers into a UCS Manager domain, which allows them to be managed with the same service profile methodology as the blades. This provides architectural flexibility, allowing organizations to use rack servers for workloads that require large amounts of local storage or specialized PCIe cards that do not fit in a blade form factor. To integrate a C-Series server into a UCS domain, it must be connected to the Fabric Interconnects. This can be done in several ways. One method involves connecting the server's VIC adapter directly to the Fabric Interconnects. Another popular method, especially for scaling out multiple rack servers, is to use a Fabric Extender, such as the Nexus 2000 series. This acts as a top-of-rack concentrator, similar to the IOM in the blade chassis, connecting multiple servers to the Fabric Interconnects over a few high-speed links. Regardless of the connection method, once integrated, the C-Series server can have a service profile applied, making its management experience identical to that of a B-Series blade.

Comparing B-Series and C-Series Use Cases

A key aspect of data center architecture, and a relevant consideration stemming from the 640-911 Exam knowledge base, is deciding when to use blade servers versus rack servers. UCS B-Series blades are ideal for high-density computing environments where the workloads are largely homogeneous. They excel for virtualization clusters, large web farms, and virtual desktop infrastructure (VDI) because of their smaller footprint, lower power and cooling costs per server, and simplified cabling. The shared infrastructure of the 5108 chassis makes scaling out these environments extremely efficient. On the other hand, UCS C-Series rack servers are better suited for specific use cases. They are the preferred choice for applications that demand a large amount of internal storage, such as big data nodes, storage servers, or certain types of databases. Their standard rack form factor also allows for the use of a wide variety of third-party PCIe cards, such as GPUs for high-performance computing or specialized hardware accelerators. By allowing both B-Series and C-Series to be managed under a single UCS Manager domain, Cisco provides the flexibility to use the right form factor for the right job without creating separate management silos.

Server Memory and CPU Considerations

While the 640-911 Exam focused heavily on the unique aspects of the UCS architecture, a solid understanding of fundamental server components like CPUs and memory was also expected. Cisco's B-Series and C-Series servers are based on industry-standard Intel Xeon processors. When designing or configuring a UCS server, selecting the appropriate CPU is critical. This decision involves balancing the number of cores, the clock speed, the cache size, and the power consumption to match the performance requirements of the application workload. The number of CPU sockets on the server (typically one, two, or four) is a primary determinant of its overall compute capacity. Memory configuration is equally important and often more complex. Modern servers have multiple memory channels per CPU, and for optimal performance, DIMMs should be installed in a balanced configuration across these channels. UCS Manager provides visibility into the server's memory population and health. An administrator must understand concepts like memory mirroring and memory sparing, which can be configured in the BIOS policies within a service profile to enhance reliability. The 640-911 Exam would expect a candidate to know how to create and apply policies that control these low-level hardware settings, reinforcing the concept of complete server configuration through software.

Local Storage Options and RAID Configuration

Even in an era of centralized storage area networks (SANs), local storage within the server remains crucial for operating systems, hypervisors, and certain applications. Both B-Series and C-Series servers offer options for internal hard disk drives (HDDs) or solid-state drives (SSDs). B-Series blades typically have two to four front-accessible, hot-swappable drive bays for small form factor (2.5-inch) drives. C-Series rack servers, with their larger physical size, can support a much greater number and variety of drives, including larger 3.5-inch disks. A critical skill for any server administrator, and a topic covered in the 640-911 Exam, is the configuration of Redundant Array of Independent Disks (RAID). Most UCS servers include an onboard RAID controller or support for a dedicated mezzanine or PCIe RAID card. Through UCS Manager, administrators can create a Local Disk Configuration Policy. This policy defines the RAID level (e.g., RAID 0, RAID 1, RAID 5, RAID 6) for the server's virtual drives. When this policy is included in a service profile and applied to a server, UCS Manager automatically configures the local RAID controller, further demonstrating the power of policy-based management to automate and standardize hardware setup.

The Physical and Logical Connectivity Model

To tie all the hardware concepts together, it is essential to understand the end-to-end connectivity model, a major theme of the 640-911 Exam. Physically, a blade server has a VIC adapter that connects to the chassis midplane. The midplane connects to two IOMs. Each IOM connects via one or more physical cables to one of the two Fabric Interconnects. This creates a fully redundant physical path from the server to the management and data fabric. The Fabric Interconnects then connect upstream to the external LAN and SAN switches. Logically, this physical path is a conduit for the virtualized interfaces. Within the service profile, an administrator creates a vNIC. This vNIC is assigned a MAC address from a pool and is associated with one or more VLANs. The vNIC is also pinned to one of the physical fabric paths (Fabric A or Fabric B) or configured for failover between them. Similarly, a vHBA is created, assigned a WWPN from a pool, and associated with a VSAN. This software-defined I/O configuration is pushed down to the VIC, which then presents these virtual adapters to the operating system. This complete abstraction of logical I/O from the physical hardware is the ultimate expression of the UCS vision.

Unlocking Infrastructure as Code: Cisco UCS Management for the 640-911 Exam

Having explored the foundational architecture and the specific hardware components of the Cisco Unified Computing System (UCS) in the previous installments, this third part of the series will focus on the heart of the system: management and networking. Success with the 640-911 Exam was impossible without a masterful understanding of Cisco UCS Manager (UCSM) and the logical constructs used to define and control the infrastructure. This section will provide an in-depth look at Service Profiles, the policies and pools that comprise them, and the implementation of Role-Based Access Control (RBAC) for secure administration. Furthermore, we will dissect the networking configuration within UCS, covering the setup of VLANs, VSANs, vNICs, and vHBAs, and exploring the different operating modes of the Fabric Interconnects. This is where the true power of UCS's policy-driven, automated approach to infrastructure becomes evident.

The Centrality of Service Profiles

The Service Profile is the single most important concept in UCS management and was a major focus of the 640-911 Exam. It is the logical definition of a server, containing every piece of information required to configure its identity and behavior. This includes hardware identifiers like UUID, MAC addresses for network interfaces, and World Wide Names (WWNs) for storage adapters. It also includes configuration policies for BIOS settings, boot order, RAID configuration, firmware versions, and network and storage connectivity. Essentially, a service profile turns a piece of physical hardware into a functional, application-ready server. This abstraction of identity from hardware is what enables the stateless computing model. A service profile can be created independently of any physical server. It can then be associated with a physical blade or rack server to provision it. If that server hardware fails, the administrator can simply disassociate the profile and associate it with a spare server. The new server will instantly adopt the exact same identity and configuration, dramatically reducing downtime and simplifying hardware replacement. This agility is a core benefit of the UCS platform. Service profiles can also be templated, allowing for the rapid and consistent deployment of hundreds of servers.

Deconstructing Service Profile Policies

A service profile is not a monolithic object; it is a container that brings together a multitude of individual policies. This modular approach, a key area for the 640-911 Exam, allows for reusability and standardization. For instance, an organization might create a single "Boot-from-SAN-Policy-FabricA" that is used in hundreds of different service profiles. If the boot LUN path ever changes, an administrator only needs to update that one policy, and the change will automatically propagate to all associated servers. Some of the most common policies that make up a service profile include the Local Disk Configuration Policy, which defines the RAID level for internal drives. The Boot Policy dictates the order in which the server attempts to boot from different devices (e.g., local disk, SAN, PXE). The BIOS Policy controls low-level hardware settings like CPU performance options and power management. The Host Firmware Package policy ensures that the server's adapters, CIMC, and BIOS are all running a specific, tested combination of firmware versions. Mastering the creation and application of these constituent policies is fundamental to effective UCS administration.

Leveraging Pools for Scalable Identity Management

While policies define behavior, pools provide the resources needed for server identity. As covered in the 640-911 Exam curriculum, pools are collections of unique identifiers that UCS Manager can automatically assign to service profiles as they are created. This eliminates the tedious and error-prone task of manually tracking and assigning things like MAC addresses and World Wide Names. Administrators create pools for various identifier types, including MAC addresses, WWNNs (for the server node), WWPNs (for the server's virtual HBAs), and UUIDs (the universal identifier for the server hardware). When a new service profile is instantiated from a template, it requests the necessary identifiers from the appropriate pools. UCS Manager ensures that each identifier drawn from a pool is unique within the UCS domain, preventing conflicts. This automated resource management is critical for scalability. In a large environment with hundreds or thousands of servers, manually managing these unique identifiers would be an operational nightmare. Pools provide a simple yet powerful mechanism for ensuring uniqueness and consistency across the entire infrastructure, embodying the "configure once, deploy many" philosophy of UCS.

Implementing Role-Based Access Control (RBAC)

In any enterprise data center, security and controlled access are paramount. The 640-911 Exam required candidates to understand how to secure the management of the UCS platform itself. UCS Manager provides a robust Role-Based Access Control (RBAC) framework to achieve this. RBAC allows administrators to define specific roles with granular permissions and assign those roles to different users or groups of users. This ensures that individuals only have access to the tools and configurations relevant to their job function, adhering to the principle of least privilege. UCS Manager comes with a set of default roles, such as "read-only," "server-admin," and "storage-admin." However, the true power of RBAC lies in the ability to create custom roles. An administrator can define a new role and grant it a specific set of privileges, such as the ability to manage service profiles but not the ability to configure the underlying network fabric. These roles can be assigned to locally created users or, more commonly in large enterprises, integrated with external authentication services like LDAP, Active Directory, or RADIUS. This allows for centralized user management and consistent access control policies across the organization's IT systems.

Configuring LAN Connectivity and VLANs

At its core, a UCS Fabric Interconnect is a powerful network switch. A significant portion of the 640-911 Exam was dedicated to configuring its LAN connectivity features. All network traffic from the servers flows through the Fabric Interconnects, which must be connected upstream to the broader campus or data center network. This is typically done by configuring specific ports on the Fabric Interconnects as "uplink ports." These uplinks are often bundled into port-channels for increased bandwidth and redundancy. Once the physical uplinks are established, the administrator must define the virtual network landscape. This is primarily done by creating Virtual Local Area Networks (VLANs) within UCS Manager. Each VLAN created in UCSM is given a name and a VLAN ID, which must correspond to the VLANs configured on the upstream network switches. These VLANs are then made available to the servers. When creating a vNIC within a service profile, the administrator specifies which VLANs that vNIC is allowed to access. This allows for the segmentation of traffic (e.g., for different applications, tenants, or environments like production and development) at the server level.

Understanding Fabric Interconnect Operating Modes

A crucial networking decision an administrator must make during the initial setup of a UCS domain is the operating mode of the Fabric Interconnects. The 640-911 Exam tested knowledge of these modes and their implications. The two primary modes are Ethernet Switching Mode and Ethernet End-Host Mode. In Switching Mode, which is the default, the Fabric Interconnect acts like a standard Ethernet switch. It learns MAC addresses on its uplink ports and server-facing ports and makes forwarding decisions based on its MAC address table. It can also participate in the Spanning Tree Protocol (STP) to prevent network loops. In End-Host Mode, the Fabric Interconnect's behavior changes significantly. It pins all MAC addresses from the servers to the uplink ports. From the perspective of the upstream network, the entire UCS domain looks like a large host with many network adapters, not a switch. This eliminates the need for the Fabric Interconnect to run STP, as loops are not possible in this configuration. The choice between these modes depends on the specific network architecture and requirements. End-Host Mode is often preferred for its simplicity and for avoiding complex STP interactions with the core network.

Creating and Managing Virtual NICs (vNICs)

Virtual Network Interface Cards, or vNICs, are the logical network interfaces that are presented to the operating system of a UCS server. As a core topic of the 640-911 Exam, mastering vNIC creation and management is essential. A vNIC is created within a service profile and is not tied to a specific physical adapter port. It is a purely logical construct defined in software. When creating a vNIC, an administrator assigns it a MAC address (typically from a pool) and associates it with one or more VLANs. The primary VLAN is specified as the native VLAN, while others are tagged. Furthermore, the vNIC is associated with one of the two physical fabrics (Fabric A or Fabric B). For redundancy, a common practice is to create pairs of vNICs for the same function (e.g., vNIC-Mgmt-A and vNIC-Mgmt-B), with one on each fabric. The operating system can then use standard NIC teaming or bonding to provide high availability. The administrator can also apply Quality of Service (QoS) policies to vNICs to guarantee a certain amount of bandwidth for critical traffic. This level of granular, policy-based control over server networking is a key advantage of the UCS platform.

Configuring SAN Connectivity and VSANs

In addition to handling LAN traffic, the unified fabric is also designed to carry storage traffic. The 640-911 Exam required a deep understanding of how to configure SAN connectivity for boot-from-SAN and data access scenarios. The Fabric Interconnects can be configured to operate in Fibre Channel Switching Mode, connecting to an existing SAN fabric, or in Fibre Channel NPV (N-Port Virtualization) mode. In NPV mode, the Fabric Interconnect acts as a pass-through device, presenting the server vHBAs directly to the upstream SAN switches, which simplifies management and administration. Similar to VLANs for LAN traffic, Virtual SANs (VSANs) are used to segment storage traffic. An administrator defines VSANs within UCS Manager, ensuring their IDs match the VSANs configured on the upstream MDS or other Fibre Channel switches. These VSANs are then made available to the servers. When a virtual HBA (vHBA) is created in a service profile, it is explicitly associated with a specific VSAN. This ensures that the server can only see and access storage LUNs that have been provisioned on that particular VSAN, providing a critical layer of security and isolation in a shared storage environment.

Creating and Managing Virtual HBAs (vHBAs)

A Virtual Host Bus Adapter, or vHBA, is the logical equivalent of a physical Fibre Channel HBA. It is the interface that allows a UCS server to connect to and communicate with a SAN fabric. Within the 640-911 Exam context, configuring vHBAs was a critical skill for enabling enterprise storage features. Like a vNIC, a vHBA is a logical construct created within a service profile. Each vHBA is assigned a unique World Wide Port Name (WWPN), usually drawn from a pool. The server itself is assigned a World Wide Node Name (WWNN). These WWNs are used by the SAN fabric for zoning, which controls which servers can access which storage arrays. Each vHBA is tied to a specific fabric (Fabric A or Fabric B) to provide a fully redundant, multi-path connection to the SAN. An administrator will typically create at least two vHBAs per server, one for each fabric. The server's operating system, with the help of multi-pathing software, can then use both paths simultaneously for load balancing and high availability. If one fabric path fails, all storage I/O will automatically fail over to the remaining path, ensuring uninterrupted access to data. This robust, policy-driven approach to SAN connectivity is a hallmark of the UCS system.

UCS Infrastructure Maintenance and Virtualization for the 640-911 Exam

Following our deep dive into the management and networking fabric of the Cisco Unified Computing System (UCS), this fourth part of the series addresses storage integration, virtualization, and essential system maintenance tasks. The knowledge required for the 640-911 Exam extended beyond initial setup and configuration; it demanded proficiency in ongoing operational duties and an understanding of how UCS interacts with the hypervisors that run on it. This section will explore the intricacies of storage connectivity, focusing on Fibre Channel, FCoE, and iSCSI. We will also examine the integration with virtualization platforms like VMware vSphere, the critical process of firmware management, and the high-availability features of the UCS platform. These topics represent the day-to-day reality of a UCS administrator and were crucial for demonstrating comprehensive expertise.

Deep Dive into Storage Connectivity

Effective data center operations rely on robust and resilient storage connectivity, a topic given significant weight in the 640-911 Exam. Cisco UCS provides multiple pathways to connect servers to centralized storage systems. The most common method in enterprise environments is Fibre Channel (FC). As discussed previously, this is achieved by creating virtual HBAs (vHBAs) on the server's VIC adapter, which then communicate over the unified fabric through the Fabric Interconnects to an upstream SAN switch. This method is renowned for its high performance and reliability, making it ideal for mission-critical applications and databases. Another prominent technology within UCS is Fibre Channel over Ethernet (FCoE). FCoE is an encapsulation protocol that allows Fibre Channel frames to be transported over a 10 Gigabit or faster Ethernet network. The unified fabric is natively capable of handling FCoE traffic. This allows for further convergence, as a single physical Ethernet connection from the server can carry both traditional IP-based LAN traffic and encapsulated FC SAN traffic. This reduces the number of required adapters and cables, aligning perfectly with the core UCS philosophy of simplification. The configuration from the server's perspective remains very similar, still utilizing a vHBA.

Configuring iSCSI and NAS Connectivity

While Fibre Channel and FCoE are prevalent for block storage, many environments also utilize Network Attached Storage (NAS) and iSCSI. The 640-911 Exam curriculum acknowledged the importance of these IP-based storage protocols. NAS, which provides file-level access using protocols like NFS or CIFS/SMB, is straightforward to implement in UCS. Since it is standard IP traffic, it is handled by the server's vNICs and transported over the configured VLANs just like any other network data. No special hardware or configuration is needed beyond standard LAN connectivity. Internet Small Computer System Interface (iSCSI) provides block-level storage access over an IP network. To configure a server for iSCSI booting or data access, an administrator would provision one or more vNICs dedicated to iSCSI traffic. These vNICs are often placed in their own separate, non-routable VLAN for security and performance isolation. The operating system or hypervisor then uses a software iSCSI initiator to connect to the storage array's iSCSI target. For improved performance, some VIC adapters support iSCSI offload, which processes the iSCSI protocol in hardware, reducing the CPU overhead on the server.

Integration with VMware vSphere

In the modern data center, server hardware rarely runs a single operating system directly. Instead, it typically runs a hypervisor, and the most common enterprise hypervisor is VMware vSphere. The 640-911 Exam required a solid understanding of how UCS integrates with and enhances a vSphere environment. The synergy between the two platforms is significant. UCS's stateless computing model, enabled by service profiles, allows administrators to quickly provision new ESXi hosts or replace failed ones with minimal effort, which is a huge benefit for managing large virtualization clusters. The I/O virtualization capabilities of the Cisco VIC adapter are also a major advantage. A VIC can present multiple vNICs to an ESXi host. These can then be assigned to different virtual switches (vSwitches) or distributed virtual switches (DVS) within vCenter Server for different purposes, such as virtual machine traffic, vMotion, management, and fault tolerance logging. This hardware-level separation provides better performance and security isolation than relying solely on VLAN tagging on a single virtual switch. Cisco also provides plugins for vCenter that allow virtualization administrators to have visibility into the underlying UCS physical infrastructure directly from the vSphere client.

Understanding Cisco UCS Director

While UCS Manager is excellent for managing the UCS domain itself, modern data centers require orchestration across multiple domains, including compute, network, storage, and virtualization. For this, Cisco offers UCS Director, an automation and orchestration platform. While advanced orchestration was a broader topic, awareness of its role was beneficial for those studying for the 640-911 Exam. UCS Director provides a single portal for managing and automating a complete converged infrastructure stack. It integrates with UCS Manager, Nexus switches, MDS storage switches, and various storage arrays and hypervisors. Using UCS Director, an administrator can create end-to-end provisioning workflows. For example, a workflow could be designed to automatically deploy a new three-tier application. This single workflow could provision a new service profile in UCS Manager, configure the necessary VLANs on the network switches, provision a LUN on the storage array and zone it to the new server, and finally deploy a virtual machine from a template onto the newly provisioned ESXi host. This level of multi-domain automation dramatically accelerates service delivery and reduces the potential for manual configuration errors, representing the next step in the evolution of policy-based data center management.

The Critical Importance of Firmware Management

Keeping firmware and drivers up-to-date is a critical but often challenging task in any server environment. Inconsistent firmware levels across servers can lead to unpredictable behavior, performance issues, and security vulnerabilities. Cisco UCS provides a powerful, policy-based solution to this challenge, a key operational topic for the 640-911 Exam. Within UCS Manager, administrators can define Host Firmware Packages. A Host Firmware Package is a collection of specific firmware versions for all the different components of a server, including the BIOS, the Cisco Integrated Management Controller (CIMC), the VIC adapter, and RAID controllers. This package is then associated with a service profile. When the service profile is applied to a server, UCS Manager automatically compares the running firmware on the hardware with the versions specified in the policy. If there is a mismatch, it can trigger a firmware update to bring the server into compliance. This centralized, policy-driven approach ensures that all servers of a certain type are running the exact same, fully tested firmware stack. This standardization simplifies troubleshooting and makes the entire infrastructure more stable and predictable. The process can be automated, allowing for rolling updates across a cluster with minimal disruption.

High Availability and Redundancy Features

The Cisco UCS platform was designed from the ground up for high availability, a concept that is woven throughout the 640-911 Exam objectives. Redundancy is built into every level of the architecture. The Fabric Interconnects are deployed as a clustered pair. If one Fabric Interconnect fails, the other takes over all management and data plane responsibilities seamlessly. The blade chassis supports redundant power supplies and fans. The connections from the chassis IOMs to the Fabric Interconnects are also redundant, with IOM A connecting to Fabric Interconnect A and IOM B connecting to Fabric Interconnect B. This redundancy extends all the way to the server itself. Each blade server connects to both IOMs via the chassis midplane, providing two independent I/O paths. By creating virtual interfaces (vNICs and vHBAs) on both Fabric A and Fabric B and using operating system-level teaming or multi-pathing, there is no single point of failure in the data path from the application to the network or storage fabric. This end-to-end redundancy is a core design principle of UCS and is essential for supporting enterprise-class workloads that require maximum uptime and reliability.

Backup and Restore Procedures for UCS Manager

Given that the entire configuration of the UCS domain is stored within the UCS Manager database on the Fabric Interconnects, protecting this configuration is critically important. The 640-911 Exam curriculum included coverage of backup and restore procedures. UCS Manager provides robust features for backing up the system configuration. Administrators can perform a full state backup, which captures the entire configuration of the system, including all service profiles, policies, pools, VLANs, and hardware information. These backups can be scheduled to run automatically and can be stored on a remote server via protocols like FTP, SFTP, or SCP. In the event of a catastrophic failure where the configuration is lost or corrupted, or if a Fabric Interconnect needs to be replaced, this backup file can be used to restore the entire system to its last known good state. UCS Manager also supports configuration import and export features, which are useful for replicating configurations between different UCS domains or for backing up specific logical parts of the configuration. Understanding how to properly protect and, if necessary, restore the UCS Manager configuration is a fundamental skill for any UCS administrator, ensuring business continuity.

System Monitoring, Logging, and Fault Management

Effective operational management requires proactive monitoring and rapid fault detection. UCS Manager provides a comprehensive suite of tools for this purpose. The 640-911 Exam expected candidates to be familiar with monitoring the health of the UCS domain. The UCS Manager GUI provides a detailed overview of the entire system, with clear indications of the operational status of every component, from individual DIMMs and disks within a server to the Fabric Interconnects themselves. The system uses a robust fault management system, where any hardware or software issue generates a fault. These faults are collected and displayed in the fault summary, allowing administrators to quickly identify and diagnose problems. For more in-depth analysis and long-term trending, UCS Manager can be configured to send its logs to a remote syslog server. It can also send alerts and notifications via SNMP traps or email alerts when specific thresholds are exceeded or critical faults occur. This proactive monitoring allows administrators to address potential issues before they cause a service outage, which is key to maintaining a healthy and stable infrastructure.

Advanced Topics and the Legacy of the 640-911 Exam

In this final installment of our comprehensive series on the technologies of the 640-911 Exam, we will explore advanced concepts, troubleshooting methodologies, and the lasting impact of this certification on the data center industry. While the previous parts covered the hardware, management, networking, and maintenance fundamentals, this section will delve into programmatic control via the XML API and PowerShell, advanced troubleshooting techniques, and the evolution of Cisco's data center certification path. The 640-911 Exam was not just about day-one configuration; it was about having the deep knowledge required to operate, optimize, and repair the environment. Understanding these advanced topics provides a complete picture of the skills a UCS expert was expected to possess and demonstrates how these foundational principles continue to be relevant in the age of infrastructure automation and cloud computing.


Go to testing centre with ease on our mind when you use Cisco 640-911 vce exam dumps, practice test questions and answers. Cisco 640-911 Introducing Cisco Data Center Networking (DCICN) certification practice test questions and answers, study guide, exam dumps and video training course in vce format to help you study with ease. Prepare with confidence and study using Cisco 640-911 exam dumps & practice test questions and answers vce from ExamCollection.

Read More


SPECIAL OFFER: GET 10% OFF

Pass your Exam with ExamCollection's PREMIUM files!

  • ExamCollection Certified Safe Files
  • Guaranteed to have ACTUAL Exam Questions
  • Up-to-Date Exam Study Material - Verified by Experts
  • Instant Downloads

SPECIAL OFFER: GET 10% OFF

Use Discount Code:

MIN10OFF

A confirmation link was sent to your e-mail.
Please check your mailbox for a message from support@examcollection.com and follow the directions.

Download Free Demo of VCE Exam Simulator

Experience Avanset VCE Exam Simulator for yourself.

Simply submit your e-mail address below to get started with our interactive software demo of your free trial.

sale-70-410-exam    | Exam-200-125-pdf    | we-sale-70-410-exam    | hot-sale-70-410-exam    | Latest-exam-700-603-Dumps    | Dumps-98-363-exams-date    | Certs-200-125-date    | Dumps-300-075-exams-date    | hot-sale-book-C8010-726-book    | Hot-Sale-200-310-Exam    | Exam-Description-200-310-dumps?    | hot-sale-book-200-125-book    | Latest-Updated-300-209-Exam    | Dumps-210-260-exams-date    | Download-200-125-Exam-PDF    | Exam-Description-300-101-dumps    | Certs-300-101-date    | Hot-Sale-300-075-Exam    | Latest-exam-200-125-Dumps    | Exam-Description-200-125-dumps    | Latest-Updated-300-075-Exam    | hot-sale-book-210-260-book    | Dumps-200-901-exams-date    | Certs-200-901-date    | Latest-exam-1Z0-062-Dumps    | Hot-Sale-1Z0-062-Exam    | Certs-CSSLP-date    | 100%-Pass-70-383-Exams    | Latest-JN0-360-real-exam-questions    | 100%-Pass-4A0-100-Real-Exam-Questions    | Dumps-300-135-exams-date    | Passed-200-105-Tech-Exams    | Latest-Updated-200-310-Exam    | Download-300-070-Exam-PDF    | Hot-Sale-JN0-360-Exam    | 100%-Pass-JN0-360-Exams    | 100%-Pass-JN0-360-Real-Exam-Questions    | Dumps-JN0-360-exams-date    | Exam-Description-1Z0-876-dumps    | Latest-exam-1Z0-876-Dumps    | Dumps-HPE0-Y53-exams-date    | 2017-Latest-HPE0-Y53-Exam    | 100%-Pass-HPE0-Y53-Real-Exam-Questions    | Pass-4A0-100-Exam    | Latest-4A0-100-Questions    | Dumps-98-365-exams-date    | 2017-Latest-98-365-Exam    | 100%-Pass-VCS-254-Exams    | 2017-Latest-VCS-273-Exam    | Dumps-200-355-exams-date    | 2017-Latest-300-320-Exam    | Pass-300-101-Exam    | 100%-Pass-300-115-Exams    |
http://www.portvapes.co.uk/    | http://www.portvapes.co.uk/    |