Recent content by stormkroe

  1. Changed light switches out, now only 1 works correctly :/

    Sounds like you got a your constant power connected to a switch in place of the 'power-out' that should have been there. For real diagnostics, pull the cover, unscrew the switches, gently pull them out so the wires are all visible and send us a screen shot. This kind of thing is super easy to...
  2. Question on Electrical Wiring

    It's been a while since I did much electrical stateside (though I think that's about to change), but up here in the great white north the identification is only necessary at the fixture. That's why we ALWAYS send constant power down the white, then back up on the black. As the white wire in...
  3. Question on Electrical Wiring

    Romex switch legs always contain a white unless you buy some kind of really rare NM without a white in it. Constant power in the light JB goes down to the switch on the white, back up on the black. Can you produce a code against that? I've never seen one.
  4. Question on Electrical Wiring

    The confusing part is that, if there are only 2 conductors in the box like OP stated, one of them should be white because it would be what's called a 'switch leg', which is 99.999% of the time done with a 14/2 romex in residential. So the original electrician used some kind of really REALLY...
  5. Question on Electrical Wiring

    OP, repurpose one of the conductors in the switch into a neutral and replace the switch with a receptacle. This moves your 'problem' back out to the light, which can be solved easily with a pull chain or occupancy sensor. It can be solved with more difficulty by surface mounting a BX or...
  6. New furnace with heat pump added opinions please

    That seems insanely expensive to me. Is the $3k blower included in the $8k install price at least? Or is the $5k heat pump in there? A furnace swap that only needs minor duct adaptation takes 2-5 hours labor. Also, i would note that the chb105 is ENORMOUS for 1064 sq ft. I have a 95k btu...
  7. <SOFTWARE RANT>.... You buy a peice of software for 1000 bucks........

    I hate how people crash space ships like Columbia... they probably thought flying one was as easy as buying an airplane with a manufacturer's manual or something.
  8. Quick advice on rim joist insulation

    @Greenman what you're seeing is the non load-bearing side of one of my dormers. The house is very tall because we decided to spend the extra $3k to use attic trusses, and I gained another 900 sq ft for the house. The insulation is that way because I claimed just about every cubic foot of space...
  9. Quick advice on rim joist insulation

    I did fibreglass capped with 3"+ foam for extra R and vapor barrier in my attic.
  10. If possible: Forced birth control for those on welfare to stop the next generation of poor

    Hey, where have you been for the last 4 YEARS? And this is what we call 'hitting the ground running' lol.
  11. Quick advice on rim joist insulation

    OP, if your heart is set on this, save yourself 750% of the labor and buy a Froth Pak. It will get in every single little hole/crack (you won't the other way, no matter how diligent you are), it's fairly inexpensive for what it is, and it's also a vapor barrier (so there's no 'in between' space...
  12. House wiring/breaker box limits question

    OP 60 amp breaker for a stove is ENOURMOUS. They're usually on a 2p40, and even then I've never seen one draw over 28A with a clampon (maybe in self cleaning mode and burners on too?) As long as you don't bake a turkey, dry your clothes, run your AC and microwave popcorn all at the same time...
  13. Motion Light woes-

    Is it mounted on the wall or i the soffit? If the wall, you could pull the box out, drill through into the building, and stuff a BX through the hole. Strap it down the inside wall (ugly, but OK in a garage), or hit the back of another JB, then pipe down to a switch at normal height.
  14. Motion Light woes-

    LEF suffers from TREMENDOUS inrush current, that's why dimmers are rated differently for LEDs than they are for incandescents (usually between 1/4 and 1/6 the wattage rating). More than likely, the little relay inside the motion detector can't handle the over current situation. You could use...
  15. Change CFL kitchen lights to LED?

    More than likely, what you're experiencing is a better CRI (color rendering index), as color temp has little to do with accuracy at about 2500k and above. I usually shoot for 3k in hotels and houses, although i love 5k or even 6.5k (as close to actual summer sunshine as you can usually get) in...
sale-70-410-exam    | Exam-200-125-pdf    | we-sale-70-410-exam    | hot-sale-70-410-exam    | Latest-exam-700-603-Dumps    | Dumps-98-363-exams-date    | Certs-200-125-date    | Dumps-300-075-exams-date    | hot-sale-book-C8010-726-book    | Hot-Sale-200-310-Exam    | Exam-Description-200-310-dumps?    | hot-sale-book-200-125-book    | Latest-Updated-300-209-Exam    | Dumps-210-260-exams-date    | Download-200-125-Exam-PDF    | Exam-Description-300-101-dumps    | Certs-300-101-date    | Hot-Sale-300-075-Exam    | Latest-exam-200-125-Dumps    | Exam-Description-200-125-dumps    | Latest-Updated-300-075-Exam    | hot-sale-book-210-260-book    | Dumps-200-901-exams-date    | Certs-200-901-date    | Latest-exam-1Z0-062-Dumps    | Hot-Sale-1Z0-062-Exam    | Certs-CSSLP-date    | 100%-Pass-70-383-Exams    | Latest-JN0-360-real-exam-questions    | 100%-Pass-4A0-100-Real-Exam-Questions    | Dumps-300-135-exams-date    | Passed-200-105-Tech-Exams    | Latest-Updated-200-310-Exam    | Download-300-070-Exam-PDF    | Hot-Sale-JN0-360-Exam    | 100%-Pass-JN0-360-Exams    | 100%-Pass-JN0-360-Real-Exam-Questions    | Dumps-JN0-360-exams-date    | Exam-Description-1Z0-876-dumps    | Latest-exam-1Z0-876-Dumps    | Dumps-HPE0-Y53-exams-date    | 2017-Latest-HPE0-Y53-Exam    | 100%-Pass-HPE0-Y53-Real-Exam-Questions    | Pass-4A0-100-Exam    | Latest-4A0-100-Questions    | Dumps-98-365-exams-date    | 2017-Latest-98-365-Exam    | 100%-Pass-VCS-254-Exams    | 2017-Latest-VCS-273-Exam    | Dumps-200-355-exams-date    | 2017-Latest-300-320-Exam    | Pass-300-101-Exam    | 100%-Pass-300-115-Exams    |
http://www.portvapes.co.uk/    | http://www.portvapes.co.uk/    |