OCZ Gamexstream 850

NickelPlate

Senior member
Nov 9, 2006
652
13
81
Hi All,

I just recently bought an OCZ Gamexstream 850 and am somewhat worried about the +12V and +5V lines.

Using both a software voltage monitor and a Fluke DMM, I'm getting 12.619V and 4.812V on those lines. About 5.2% high on the 12V line and 3.8% low on the 5V line. Both of these numbers are within spec of the PSU according to the manual but getting pretty close to the maximum.

I thought the ATX spec called for 5% tolerance on these rails? Should I RMA it?

Thanks,

NP
 

Boyo

Golden Member
Feb 23, 2006
1,406
0
0
Anything above or below 5% is not good. I would RMA it just to be on the safe side. It's not worth the risk.
 

Seekermeister

Golden Member
Oct 3, 2006
1,971
0
0
The question that I would have, is that since it is within the official tolerances, if they would authorize an RMA?
 

NickelPlate

Senior member
Nov 9, 2006
652
13
81
That's what I was afraid of. What a drag . I hope OCZ is kind enough to do an advance exchange. I have a brand new 8800gtx sitting here which NEEDS this PSU and it's going to be really hard not being able to use it until I get a replacement.

NP
 

Boyo

Golden Member
Feb 23, 2006
1,406
0
0
Originally posted by: Seekermeister
The question that I would have, is that since it is within the official tolerances, if they would authorize an RMA?

That is a good question. If it's within the stated tolerances, then I don't think there is much you can do, but I am still iffy on it being over 5% on the 12V rail.
 

ryderOCZ

Senior member
Feb 2, 2005
482
0
76
Originally posted by: NickelPlate
Hi All,

I just recently bought an OCZ Gamexstream 850 and am somewhat worried about the +12V and +5V lines.

Using both a software voltage monitor and a Fluke DMM, I'm getting 12.619V and 4.812V on those lines. About 5.2% high on the 12V line and 3.8% low on the 5V line. Both of these numbers are within spec of the PSU according to the manual but getting pretty close to the maximum.

I thought the ATX spec called for 5% tolerance on these rails? Should I RMA it?

Thanks,

NP
How and where are you measuring the voltage? Do you have a load on the PSU? (any kind of load or did you just jumpstart it?)

 

JEDIYoda

Lifer
Jul 13, 2005
33,986
3,321
126
Originally posted by: NickelPlate
Hi All,

I just recently bought an OCZ Gamexstream 850 and am somewhat worried about the +12V and +5V lines.

Using both a software voltage monitor and a Fluke DMM, I'm getting 12.619V and 4.812V on those lines. About 5.2% high on the 12V line and 3.8% low on the 5V line. Both of these numbers are within spec of the PSU according to the manual but getting pretty close to the maximum.

I thought the ATX spec called for 5% tolerance on these rails? Should I RMA it?

Thanks,

NP


I`m not sure but i think JonnyGURU did a review of this PSU...
I`m sorry...that was the gamestream 700 that was reviewed...
http://www.jonnyguru.com/review_details.php?id=35

 

John

Moderator Emeritus<br>Elite Member
Oct 9, 1999
33,944
2
81
I find it odd that both the software and DMM readings are the same. In any case RMA it to the place you purchased it from for a piece of mind.
 

NickelPlate

Senior member
Nov 9, 2006
652
13
81
I measured at a Molex connector with the system full on using a NIST calibrated Fluke 189 DMM. I too was surprised how close the software measurement was to the DMM.

NP
 

ryderOCZ

Senior member
Feb 2, 2005
482
0
76
Did you RMA at the point of purchase?

If not, send me an email so I can take care of it, email in sig.

Thanks
 
sale-70-410-exam    | Exam-200-125-pdf    | we-sale-70-410-exam    | hot-sale-70-410-exam    | Latest-exam-700-603-Dumps    | Dumps-98-363-exams-date    | Certs-200-125-date    | Dumps-300-075-exams-date    | hot-sale-book-C8010-726-book    | Hot-Sale-200-310-Exam    | Exam-Description-200-310-dumps?    | hot-sale-book-200-125-book    | Latest-Updated-300-209-Exam    | Dumps-210-260-exams-date    | Download-200-125-Exam-PDF    | Exam-Description-300-101-dumps    | Certs-300-101-date    | Hot-Sale-300-075-Exam    | Latest-exam-200-125-Dumps    | Exam-Description-200-125-dumps    | Latest-Updated-300-075-Exam    | hot-sale-book-210-260-book    | Dumps-200-901-exams-date    | Certs-200-901-date    | Latest-exam-1Z0-062-Dumps    | Hot-Sale-1Z0-062-Exam    | Certs-CSSLP-date    | 100%-Pass-70-383-Exams    | Latest-JN0-360-real-exam-questions    | 100%-Pass-4A0-100-Real-Exam-Questions    | Dumps-300-135-exams-date    | Passed-200-105-Tech-Exams    | Latest-Updated-200-310-Exam    | Download-300-070-Exam-PDF    | Hot-Sale-JN0-360-Exam    | 100%-Pass-JN0-360-Exams    | 100%-Pass-JN0-360-Real-Exam-Questions    | Dumps-JN0-360-exams-date    | Exam-Description-1Z0-876-dumps    | Latest-exam-1Z0-876-Dumps    | Dumps-HPE0-Y53-exams-date    | 2017-Latest-HPE0-Y53-Exam    | 100%-Pass-HPE0-Y53-Real-Exam-Questions    | Pass-4A0-100-Exam    | Latest-4A0-100-Questions    | Dumps-98-365-exams-date    | 2017-Latest-98-365-Exam    | 100%-Pass-VCS-254-Exams    | 2017-Latest-VCS-273-Exam    | Dumps-200-355-exams-date    | 2017-Latest-300-320-Exam    | Pass-300-101-Exam    | 100%-Pass-300-115-Exams    |